Specification
• For light to medium weight internal doors.
• Door thickness 40-44mm.
• Maximum door width normally 950mm.
• Maximum door height normally 2100mm.
• Maximum panel weight 80kg.
• Unhanded, distance between centres of the fixing plates must not exceed 52 mm in
order to allow door to open through 105°.
• Unit is concealed within door and frame; only the stainless steel rods and face plates
are exposed, when door is open.
• The sealed hydraulic unit closes the door at a controlled speed with adjustable latch/
stop action.
• Type-tested to BS EN 1154:1997 power size 3 tested for 1 hour fire doors to BS EN 1634.
• Designed and tested to 500,000 closing cycles.
Finish
• Anodised Aluminium body, stainless steel rods and face plates.
Specification
• Constructed from 3mm thick unbreakable polycarbonate with scratch resistant coating, the 360° hemisphere mirror is designed for mounting on the ceiling, thus providing 200° of vision from any direction.
• Foam backing block to prevent deformation of mirror.
• The mirror is secured in a steel flanged frame and fixed to the ceiling using tamper proof screws.
The 3G417 is a morticed sprung latchbolt of robust construction based on a small mortice footprint.
The latchbolt provides an overall throw of 32mm when deadlocked and 12mm when latched.
Specification
• Solid Case Technology; Lock case machined from single piece carbon steel.
• Steel main bolt, with carbide anti-cutting rollers, and 32mm overall bolt throw.
• 12mm sprung latch controlled by occupant.
• Independent 7-lever locking mechanism.
• Factory restricted key section.
• Anti-ligature knob and door furniture.
• Through fix design for handle and furniture.
To provide secure locking of Seclusion Room doors.
Specification
• Solid Case Technology; Lock case machined from single piece carbon steel.
• Steel main bolt, with carbide anti-cutting rollers, and 32mm throw.
• Independent 7-lever locking mechanism.
• Factory restricted key section.
• Integral baffle arrangements to resist manipulation and interference via the keyhole.
A vertical ligature resisting viewer specifically designed for varying height custody officers looking into cells.
Specification
• Home Office approved.
• Quiet, discreet louvred viewing by simply lifting the louvre handle.
• 20mm thick glass.
• 300mm high x 50mm wide clear vision.
• Solid machined one piece ligature resisting steel and aluminium body.
• Gasket free to prevent ligature attachment.
• Polycarbonate dust cover to help prevent dust penetration.
• Suits door thickness 46mm – 50mm.
• Simple clamp on design fits through hole in door.
Specification
• Max door width: 1100mm (HC0830A), 1400mm (HC0830B).
• Max door weight: 100kg (HC0830A), 180kg (HC0830B).
• Concealed closer.
• Cam action technology.
• Slide channel arm.
• Adjustable sweep speed.
• Adjustable latching speed.
• Adjustable closing force.
• Successful independent testing to BS EN 1154.
• CERTIFIRE Approved for fire doors: CF140 ITT60/MM/IMM240.
Specification
• Constructed from 4.5mm thick unbreakable polycarbonate with scratch resistant coating, the 360° hemisphere mirror is designed for mounting on the ceiling, thus providing 200° of vision from any direction.
• The mirror secured through the integral mirror flange and fixed to the ceiling using tamper proof screws.
Electro-Mechanical Mortice Lock
To provide secure locking of swinging passage / control doors using third party secu-rity management systems (SMS) or conventional key control. Designed to enable key and electric operation from both sides of the door. This lock is specifically designed for very high use applications; typically securing perimeter doors and main access routes.
Specification
• Solid Case Technology; Lock case machined from single piece carbon steel block.
• Steel main bolt, with carbide anti-cuffing rollers and 25mm throw.
• Supplied with “T” Handle as standard.
• Unique dual solenoid electric locking latch.
• Independent 8-lever locking mechanism.
• Lock provides status monitoring of critical functions and tamper.
• Integral baffle arrangements to resist manipulation and interference via the keyhole.
• Dedicated key profile operates 3R63 group of locks only.
Specification
• Home Office and Metropolitan Police approved.
• Simple single handed operation.
• When closed the patient has no view out of the room.
• At the viewing position the staff has full view into the room.
• Simple single handed press-to-release operation to open and bottom latching.
• Vertical sliding hatch is automatically secured in the viewing and closed positions.
• Cannot be opened from inside.
• Dry-wipe board and safe sign now incorporated into hatch assembly.
• Supplied with a unique adjustable aperture liner which eliminates any potential
ligature gap around the hatch aperture.
The HC0812 is ideal where the customer needs electric unlocking of deadlocks, without the worry
of handle overrides from the secure side. Fail open versions fitted to fire exit doors, linked into
fire alarm systems achieve fire safety with security.
Specification
• Standard 12v DC operation.
• Designed to suit dead bolt 10-15mm wide x 38mm height with 12-18mm throw.
• 2200lbs Strength.
To provide a means of securing wooden doors on offices and rooms where a range of suiting options is required, and/or where a high degree of protection against all known forms of vandal attack is needed.
Specification
• Steel Body.
• Brass deadbolt with 14mm bolt throw.
• Anti-padsaw steel rollers. Throw
• 5 lever mechanism with over a thousand key combinations.
• Built in protection against picking, drilling, force and torque attack.
• Brass key.
• Optional micro-switches for alarm systems integration.
• Can be suited as part of a master keyed system.
• Certified to BS3621.
The HC0813 is designed for high security applications ideal where the customer needs electric
unlocking of deadlocks, without the worry of handle overrides from the secure side. Fail open
versions fitted to fire exit doors, linked into fire alarm systems achieve fire safety with security.
Specification
• Standard 12v DC operation.
• Designed to suit dead bolt 18mm wide x 65mm height with 18-21mm throw.
• 4400lbs Strength.
CSL Healthcare
Lynstock Way
Lostock
Bolton
BL6 4SA
Tel: +44 (0) 1204 669 690